These Details are intended for
use by design professionals for the design and construction
of public improvements required to provide service to private
development but which are owned and maintained by the City
of Lake Oswego. They should also be used for the design
and construction of privately owned and maintained facilities
to be located in City owned rights-of-way and/or to be connected
to City owned facilities.
It is expected
that changes in technology, materials of construction, and
contractors' means and methods will require periodic revision
of these Details. However, modification of these Details
without express approval by the City Engineer is prohibited.
Your assistance in reporting any errors and providing suggestions
for additions, deletions or revisions to maintain these
Details is welcomed and appreciated. Inquiries regarding
current or imminent revisions, suggestions, and reports
of errors or omissions should be directed to the City Engineer.
We try to update
these details on a regular basis, however, we do not guarantee
that the most recent version will be published on this site.
To guarantee that the most up-to-date version is available
on this web site, please contact the Engineering Department at 503.635.0270 or email.
| |
Detail No. |
Description |
Date Rev. |
| |
Index |
Standard Detail Drawings
Index |
06/14/06
|
| |
| JPG |
Adobe
Acrobat |
Street |
|
| A-1.01 |
A-1.01 |
20 ft. Urban Residential
Street Section |
11/18/03 |
| A-1.02 |
A-1.02 |
24 ft. Urban Residential
Street Section |
11/18/03 |
| A-1.03 |
A-1.03 |
Typical Residential Turn-A-Round |
5/21/99 |
| A-2.01 |
A-2.01 |
Vertical Curb Detail |
4/25/05 |
| A-2.02 |
A-2.02 |
Standard Curb and Gutter
Detail |
04/26/05 |
| A-2.03 |
A-2.03 |
Mountable Curb Detail |
4/26/05 |
| A-2.04 |
A-2.04 |
Valley Gutter Detail |
6/16/98 |
| A-2.05 |
A-2.05 |
Mountable Curb Transition
to Side Inlet Catch Basin |
6/16/98 |
| A-3.01 |
A-3.01 |
Sidewalks |
12/09/05 |
| A-3.02A |
A-3.02A |
Separated Sidewalk Driveway or Alleys (Opt. H, I & J) Local Jurisdictions |
03/06/06 |
| A-3.02B |
A-3.02B |
Curb Line Sidewalk Driveways or Alleys (Opt. M & N) Local Jurisdictions |
03/06/06 |
| A-3.02C |
A-3.02C |
Non-Sidewalk Driveway Approaches Local Jurisdictions |
03/8/11 |
| A-3.03 |
A-3.03 |
Typical A.C. Path |
11/19/03 |
| A-4.01 |
A-4.01 |
Sidewalk Ramp Details |
03/06/06 |
| A-4.02 |
A-4.02 |
Sidewalk Ramp Placement |
12/09/05 |
| A-4.03 |
A-4.03 |
Typical Driveway Gradient
(profile) |
6/16/98 |
| A-4.04 |
A-4.04 |
Vertical Curves for Driveways
(Examples) |
6/16/98 |
| A-4.05 |
A-4.05 |
Commercial Driveway Approach (with Planter Strip) |
12/09/05 |
| A-4.06 |
A-4.06 |
Commercial Driveway Approach (without Planter Strip) |
03/06/06 |
| A-5.01 |
A-5.01 |
Bollard Detail |
5/24/99 |
| A-5.02 |
A-5.02 |
Town and Country Residential
Street Light |
6/16/98 |
| A-5.03 |
A-5.03 |
Typical Barricade |
5/24/99 |
| A-6.01 |
A-6.01 |
Water and Sewer Trench Backfill
Details |
11/20/03 |
| A-6.02 |
A-6.02 |
Trench and Patch Detail
for Utility Cuts in Streets Where Geotextile is Present |
6/16/98 |
| A-6.03 |
A-6.03 |
Alternate Trench Patch |
2/9/04 |
| A-6.04 |
A-6.04 |
Alternate Trench Patch |
12/5/03 |
| A-7.01 |
A-7.01 |
This Detail is no longer being used. |
|
| A-7.02 |
A-7.02 |
Local Residential Speed
Bump |
6/30/98 |
| A-7.03 |
A-7.03 |
Neighborhood Collector
Speed Bump |
6/16/98 |
| A-7.04 |
A-7.04 |
Typical Landscape Median
Curb Section |
8/20/02 |
| |
| JPG |
Adobe
Acrobat |
Sanitary Sewer & Storm Drainage |
|
| B-1.01 |
B-1.01 |
Flattop Manhole 6"
to 21" Pipe |
6/12/00 |
| B-1.02 |
B-1.02 |
Standard Manhole Details |
6/13/00 |
| B-1.02A |
B-1.02A |
48" Extended Precast
Manhole Base |
6/17/98 |
| B-1.03 |
B-1.03 |
Manhole Bases 24"-36" Pipe |
6/17/98 |
| B-1.04 |
B-1.04 |
Manhole Bases 42"
& 48" Pipe |
6/17/98 |
| B-1.05 |
B-1.05 |
Outside Drop Manhole |
6/17/98 |
| B-1.06 |
B-1.06 |
Inside Drop Manhole |
6/17/98 |
| B-1.07 |
B-1.07 |
Precast Sump (Dry Well) |
6/13/00 |
| B-1.08A |
B-1.08A |
Pollution/Flow Control
Manhole |
5/6/03 |
| B-1.08B |
B-1.08B |
Pollution/Flow Control
Manhole Details |
5/6/03 |
| B-1.09 |
B-1.09 |
Inside Drop and Connection
to Existing Manhole |
6/13/00 |
| B-1.10 |
B-1.10 |
Manhole Step |
6/17/98 |
| B-2.01 |
B-2.01 |
Standard Manhole Frame
and Cover |
4/11/07 |
| B-2.02 |
B-2.02 |
Suburban Manhole Frame |
4/15/04 |
| B-2.03 |
B-2.03 |
Watertight Manhole Frame
and Cover |
4/11/07 |
| B-3.01A |
B-3.01A |
Typical Sanitary Sewer
Cleanout (Traffic Areas Only) |
5/26/99 |
| B-3.01B |
B-3.01B |
Typical Sanitary Sewer
Cleanout (Outside Traffic Areas) |
5/27/99 |
| B-3.01C |
B-3.01C |
2" Pressure Cleanout
Assembly |
6/17/98 |
| B-4.01 |
B-4.01 |
Sanitary Sewer Strap-on
Type Tapping Tee |
5/17/04 |
| B-4.02 |
B-4.02 |
Standard Pipe Casing
Detail |
11/1/01 |
| B-4.03A |
B-4.03A |
Typical Service Lateral |
10/11/04 |
| B-4.03B |
B-4.03B |
Typical Service Lateral
Duplex (2) |
10/11/04 |
| B-4.03C |
B-4.03C |
Typical Service Lateral
(Internally Rehabilitated Mainlines) |
10/11/04 |
| B-5.01A |
B-5.01A |
Gutter and Curb Catch
Basin (CG-1) Detail "A" |
6/17/98 |
| B-5.01B |
B-5.01B |
Gutter and Curb Catch
Basin (CG-1) Detail "B" |
6/17/98 |
| B-5.01C |
B-5.01C |
Gutter and Curb Catch
Basin Frame (CG-1) |
6/17/98 |
| B-5.01D |
B-5.01D |
Gutter and Curb Catch
Basin Grate (CG-1) |
6/17/98 |
| B-5.02A |
B-5.02A |
Oversize Gutter and Curb
Inlet Catch Basin (CG-2) |
6/17/98 |
| B-5.02B |
B-5.02B |
Oversize Catch Basin
Frame |
6/17/98 |
| B-5.02C |
B-5.02C |
Oversize Catch Basin
Grate |
6/17/98 |
| B-5.03A |
B-5.03A |
Type "G" Catch
Basin |
6/13/00 |
| B-5.03B |
B-5.03B |
Type "G" Catch
Basin Frame and Grate |
6/17/98 |
| B-5.04 |
B-5.04 |
Pollution Control Box |
6/17/98 |
| B-6.01A |
B-6.01A |
Standard Ditch Inlet |
6/17/98 |
| B-6.01B |
B-6.01B |
Slanted Frame and Grate for
Ditch Inlet |
6/17/98 |
| B-6.01C |
B-6.01C |
Box Frame and Grate for
Ditch Inlet |
6/17/98 |
| B-6.01D |
B-6.01D |
Standard Ditch Inlet w/Snout & Bio-Skirt |
8/18/10 |
| B-7.01 |
B-7.01 |
Standard Roof Drain Outlet
Box for Mountable Curb |
6/17/98 |
| B-8.01 |
B-8.01 |
Typical Closed Detention
Pipe |
5/6/03 |
| B-8.02 |
B-8.02 |
Typical Parking Lot Detention
Facility |
5/6/03 |
| B-9.01 |
B-9.01 |
S.T.E.P. System (Septic
Tank Effluent Pump) Septic Tank (Top View) |
6/17/98 |
| B-9.02 |
B-9.02 |
S.T.E.P. System (Septic
Tank Effluent Pump) Septic Tank (Side View) |
6/17/98 |
| B-9.03 |
B-9.03 |
S.T.E.P. System (Septic
Tank Effluent Pump) Gravity Discharge Tank Equipment |
6/17/98 |
| B-9.04 |
B-9.04 |
S.T.E.P. System (Septic
Tank Effluent Pump) Effluent Pumping Tank Equipment |
6/17/98 |
| B-9.05 |
B-9.05 |
S.T.E.P. System (Septic
Tank Effluent Pump) Tank Riser Detail |
6/17/98 |
| B-9.06 |
B-9.06 |
S.T.E.P. System (Septic
Tank Effluent Pump) Control and Alarms |
6/17/98 |
| B-9.07 |
B-9.07 |
S.T.E.P. System (Septic
Tank Effluent Pump) Typical 2" Service Connection
Detail |
6/17/98 |
| B-9.08 |
B-9.08 |
S.T.E.P. System (Septic
Tank Effluent Pump) Typical 4" Lateral Cleanout |
6/18/98 |
| B-9.09 |
B-9.09 |
S.T.E.P. System (Septic
Tank Effluent Pump) Typical Pipe and Trench Detail |
6/18/98 |
| B-9.10 |
B-9.10 |
S.T.E.P. System (Septic
Tank Effluent Pump) 2" Pressure Cleanout Assembly |
6/18/98 |
| |
| JPG |
Adobe Acrobat |
Water |
|
| C-1.01A |
C-1.01A |
Typical Water Service
Connection Detail 1" & Smaller |
5/26/99 |
| C-1.01B |
C-1.01B |
Typical Water Service
Connection Detail 1 1/2" to 2" |
5/26/99 |
| C-1.01C |
C-1.01C |
Typical (1 1/2"
to 2") Schedule 80 PVC Water Service Connection
Detail |
1/15/02 |
| C-1.01D |
C-1.01D |
Typical Water Service
Connection Detail 3" and 4" |
1/15/02 |
| C-1.02 |
C-1.02 |
Typical Fire Sprinkling
Service Line |
6/19/98 |
| C-2.01 |
C-2.01 |
Typical 2" Blowoff
Assembly |
6/19/98 |
| C-3.01A |
C-3.01A |
Air Valve Assembly Detail |
4/15/04 |
| C-3.01B |
C-3.01B |
Standpipe Detail |
6/19/98 |
| C-4.01 |
C-4.01 |
Typical Fire Hydrant
Installation |
7/17/00 |
| C-5.01 |
C-5.01 |
Typical Concrete Straddle
Block Detail |
6/19/98 |
| C-5.02 |
C-5.02 |
Typical Straddle Block
Pipe Clamp Detail |
6/19/98 |
| C-5.03 |
C-5.03 |
Thrust Blocking Details |
6/19/98 |
| C-5.04 |
C-5.04 |
Gravity Thrust Block
Detail |
6/19/98 |
| C-6.01 |
C-6.01 |
Typical Valve Box |
6/19/98 |
| C-7.01 |
C-7.01 |
Typical Installation "Double Check Valve" Backflow Prevention Device |
6/1/99 |
| C-7.02 |
C-7.02 |
Typical Installation "Reduced Pressure" Principle Backflow Prevention
Device |
6/1/99 |
| C-7.03A |
C-7.03A |
PRV Vault Plan |
11/9/00 |
| C-7.03B |
C-7.03B |
PRV Vault Section A |
11/4/98 |
| C-8.01A |
C-8.01A |
Irrigation Control Backflow
Preventor |
11/16/04 |
| C-8.01B |
C-8.01B |
Irrigation Control Typical
Drain Valve |
3/28/02 |
| C-8.01C |
C-8.01C |
Irrigation Control Quick
Coupler Valve |
3/28/02 |
| C-8.01D |
C-8.01D |
Irrigation Control Typical
Small Irrigation Head Installation |
11/16/04 |
| C-8.01E |
C-8.01E |
Irrigation Control Typical
Carrier Sleeve |
4/25/05 |
| C-8,01F |
C-8.01F |
Irrigation Control Typical
Underdrain Crossing |
3/28/02 |
| C-8.01G |
C-8.01G |
Irrigation Control Typical
Zone Valve Installation |
3/28/02
|
| C-9.01A |
C-9.01A |
Typical Backflow Preventer
for Lawn Sprinkler Systems |
12/31/02
|
| C-9.01B |
C-9.01B |
1", 1 1/2",
2" & 2 1/2" Double Check Installation |
12/31/02
|
| C-9.01C |
C-9.01C |
Double Check Valve Assembly
Customer Owned (above ground) 3" thru 10" |
12/31/02
|
| C-9.01D |
C-9.01D |
DCVA - 3" thru 10" (for domestic service only) Below Ground Installation |
12/31/02
|
| C-9.01E |
C-9.01E |
Double Check Detector
Assembly 3" thru 10" (for fire service) |
12/31/02
|
| C-9.01F |
C-9.01F |
Double Check Detector
Assembly Customer Owned (above ground) 3" through
10" |
12/31/02
|
| C-9.01G |
C-9.01G |
Reduced Pressure Detector
Backflow Assembly 2 1/2" - 10" Customer Owned
(above ground) |
12/31/02
|
| C-9.01H |
C-9.01H |
Reduced Pressure Detector
Backflow Assembly 2 1/2" - 10" Customer Owned
in Vault |
12/31/02
|
| C-9.01I |
C-9.01I |
Reduced Pressure Backflow
Assembly 2 1/2" - 10" Customer Owned (above
ground) |
12/31/02
|
| C-9.01J |
C-9.01J |
1" Reduced Pressure
Backflow Preventer |
12/31/02
|
| C-9.01K |
C-9.01K |
1 1/2" & 2" Reduced Pressure Backflow Device |
12/31/02
|
| C-9.01L |
C-9.01L |
Reduced Pressure Backflow
Assembly Customer Owned in Vault |
12/31/02
|
| |
| JPG |
Adobe Acrobat |
Erosion Control |
|
| D-1.01 |
D-1.01 |
Biofilter Bag Inlet Protection |
12/21/04 |
| D-1.02 |
D-1.02 |
Non-Woven Catch Basin Insert Inlet Protection |
12/21/04 |
| D-1.03 |
D-1.03 |
Check Dam Biofilter Bag |
12/21/04 |
| D-1.04 |
D-1.04 |
Sediment Fence |
12/21/04 |
| D-1.05 |
D-1.05 |
Matting Slope Installation |
12/21/04 |
| D-1.06 |
D-1.06 |
Matting Channel Installation |
12/21/04 |
| D-1.07 |
D-1.07 |
Staple Table |
12/21/04 |
| D-1.08 |
D-1.08 |
Construction Entrance |
12/21/04 |
| D-1.09 |
D-1.09 |
Sidewalk Subgrade |
12/21/04 |
| D-1.10 |
D-1.10 |
Plastic Sheeting |
09/27/05 |